久久久久人妻精品一区_久久久久人妻精品区一三寸_男人用嘴添女人下身免费视频_亚洲成AV人片在线观看天堂无

WhatsApp:86 WeChat:

Shelok Conductivity Meter

Instrument characteristics

LCD Large screen LCD

Signal output Optional

Manual, automatic temperature compensation

Two relays control the switch

Upper and lower limits, hysteresis control

The electrical conductivity and temperature values are displayed on the same interface

Provide password protection to prevent misuse by non-staff

電導率計

Main technical parameters

1. Display: Digital

2. Conductivity measurement range: Cond.0.00 microsecond/cm – 200 ms/cm

3. Range selection: automatic or (automatic and manual).

4. Accuracy: Cond. ± 0.5% (1 digit).

5. Resolution: Conductivity ± 0.01us /cm at 20.0us /cm. Automatic compensation

6. Temperature setting range: 0 to 100℃

7. Temperature compensation range: 0 to 100℃ automatic.

8. Temperature coefficient setting range: 0 ~ 100℃

9. Temperature accuracy: ±0.4℃

10. Calibration: Single point or up to 5 points of standard solution.

11. Power supply: AC 220V, (changed to 110V by transformer)

12. Temperature sensors (if applicable) : 2 (extra). For the above instruments.

13. Electrode bracket: 2. (plus). (ZFDD-98 standard with 5 meters signal line K=30)

14. Electrode bracket: 2. (Extra). (Sink mounting bracket: plastic material)

15. Extra spare parts.?a) Electrode (conductance cell) : 3 sets (316L stainless steel)

16. Transmitter: ZFDDC-101C, 220VAC power supply, (changed to 110V via transformer)

17. Measuring range: 0-200ms/cm 4 ~ 20mA output

18.2 Group high-low alarm relay switching output

19. Sensor: DD-98 standard with 5 meters signal line K=30

Reviews

There are no reviews yet.

Be the first to review “Shelok Conductivity Meter”

Your email address will not be published. Required fields are marked *

Shelok Conductivity Meter

Instrument characteristics

LCD Large screen LCD

Signal output Optional

Manual, automatic temperature compensation

Two relays control the switch

Upper and lower limits, hysteresis control

The electrical conductivity and temperature values are displayed on the same interface

Provide password protection to prevent misuse by non-staff

電導率計

Main technical parameters

1. Display: Digital

2. Conductivity measurement range: Cond.0.00 microsecond/cm – 200 ms/cm

3. Range selection: automatic or (automatic and manual).

4. Accuracy: Cond. ± 0.5% (1 digit).

5. Resolution: Conductivity ± 0.01us /cm at 20.0us /cm. Automatic compensation

6. Temperature setting range: 0 to 100℃

7. Temperature compensation range: 0 to 100℃ automatic.

8. Temperature coefficient setting range: 0 ~ 100℃

9. Temperature accuracy: ±0.4℃

10. Calibration: Single point or up to 5 points of standard solution.

11. Power supply: AC 220V, (changed to 110V by transformer)

12. Temperature sensors (if applicable) : 2 (extra). For the above instruments.

13. Electrode bracket: 2. (plus). (ZFDD-98 standard with 5 meters signal line K=30)

14. Electrode bracket: 2. (Extra). (Sink mounting bracket: plastic material)

15. Extra spare parts.?a) Electrode (conductance cell) : 3 sets (316L stainless steel)

16. Transmitter: ZFDDC-101C, 220VAC power supply, (changed to 110V via transformer)

17. Measuring range: 0-200ms/cm 4 ~ 20mA output

18.2 Group high-low alarm relay switching output

19. Sensor: DD-98 standard with 5 meters signal line K=30