Shelok Remote Type Electromagnetic Flow Meter

ZFG integrated electromagnetic flow meter is mainly used to measure the volume flow of various acids, salt solutions, pulp, mud and other conductive liquids, or liquid-solid two-phase media. It is widely used in chemical industry, mining and metallurgy, water supply and drainage, sewage treatment, food, paper, sugar, port dredging and other departments.
This flow meter can be matched with display, recording instrument, totalizator or regulator to detect, accumulate.
1>Measure accuracy: ±0.5%
2>Flow range: 0.3~15m/s
3>Working temperature: -25°C~60°C
4>Flow output signal: 0~10mA/4~20mA /Pulse/MODBUS/HART
5>Supply voltage: 220VAC or 24VDC
6>Sensor connection: Flanged,Threaded connection,Clamping connection type
7>Lining material: PTFE,neoprene, polyurethane rubber, rubber acid
8>Protection class: IP67

YFM4800E

Features:

  • Measurements are not affected by fluid density, viscosity, temperature, pressure and conductivity.
  • No obstacles in the measuring tube, no pressure loss, low requirements for straight pipe section.
  • The LCD backlight type converter can be easily displayed and read in the sun or in a dark room.
  • In harsh environments, parameters can be set via infrared touch butions without opening the cover of the converter (need to be customized).
  • Flow meter with bidirectional measurement system, built-in three totalizers: positive total, reverse total and total difference.
  • It has various forms of output: current 4-20mA, pulse, frequency, rs-485, HART.
  • The converter has self-diagnosis alarm output, no-load detection alarm output, flow upper and lower limit alarm, batch control (need to be customized) and other alarm output functions.
  • Not only for general processes, but also for the measurement of ore pulp, mud, coal slurry, paper pulp and paste liquid.
  • High-pressure electromagnetic flow sensor with PFA lining technology, resistant to high pressure and negative pressure, especially suitable for petroleum, chemical and other industries.
  • Explosion-proof instruments can be used in corresponding explosion-proof places.

Working principle:

The measuring principle of electromagnetic flow meter is based on Faraday’s law of electromagnetic induction. The sensor is mainly composed of a measuring tube with an insulating lining, a pair of electrodes installed by inserting the measuring tube wall, a pair of coils and an iron core to generate a working magnetic field. When a conductive fluid flows through the measuring tube of the sensor, a voltage signal proportional to the average flow rate of the fluid will be induced on the electrode. The signal is operationally amplified and processed to achieve various display functions.

Reviews

There are no reviews yet.

Be the first to review “Shelok Remote Type Electromagnetic Flow Meter”

Your email address will not be published. Required fields are marked *

Shelok Remote Type Electromagnetic Flow Meter

ZFG integrated electromagnetic flow meter is mainly used to measure the volume flow of various acids, salt solutions, pulp, mud and other conductive liquids, or liquid-solid two-phase media. It is widely used in chemical industry, mining and metallurgy, water supply and drainage, sewage treatment, food, paper, sugar, port dredging and other departments.
This flow meter can be matched with display, recording instrument, totalizator or regulator to detect, accumulate.
1>Measure accuracy: ±0.5%
2>Flow range: 0.3~15m/s
3>Working temperature: -25°C~60°C
4>Flow output signal: 0~10mA/4~20mA /Pulse/MODBUS/HART
5>Supply voltage: 220VAC or 24VDC
6>Sensor connection: Flanged,Threaded connection,Clamping connection type
7>Lining material: PTFE,neoprene, polyurethane rubber, rubber acid
8>Protection class: IP67

YFM4800E

Features:

  • Measurements are not affected by fluid density, viscosity, temperature, pressure and conductivity.
  • No obstacles in the measuring tube, no pressure loss, low requirements for straight pipe section.
  • The LCD backlight type converter can be easily displayed and read in the sun or in a dark room.
  • In harsh environments, parameters can be set via infrared touch butions without opening the cover of the converter (need to be customized).
  • Flow meter with bidirectional measurement system, built-in three totalizers: positive total, reverse total and total difference.
  • It has various forms of output: current 4-20mA, pulse, frequency, rs-485, HART.
  • The converter has self-diagnosis alarm output, no-load detection alarm output, flow upper and lower limit alarm, batch control (need to be customized) and other alarm output functions.
  • Not only for general processes, but also for the measurement of ore pulp, mud, coal slurry, paper pulp and paste liquid.
  • High-pressure electromagnetic flow sensor with PFA lining technology, resistant to high pressure and negative pressure, especially suitable for petroleum, chemical and other industries.
  • Explosion-proof instruments can be used in corresponding explosion-proof places.

Working principle:

The measuring principle of electromagnetic flow meter is based on Faraday’s law of electromagnetic induction. The sensor is mainly composed of a measuring tube with an insulating lining, a pair of electrodes installed by inserting the measuring tube wall, a pair of coils and an iron core to generate a working magnetic field. When a conductive fluid flows through the measuring tube of the sensor, a voltage signal proportional to the average flow rate of the fluid will be induced on the electrode. The signal is operationally amplified and processed to achieve various display functions.